Back to top
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood

Laboratory Fume Hood

Price 182000.0 INR/ Piece

MOQ : 1 Unit

Laboratory Fume Hood Specification

  • Power Supply
  • 220-240 V
  • Temperature Resistance
  • Yes
  • Shape
  • Rectangular
  • Control Type
  • Keypad
  • Display Type
  • Digital
  • Usage
  • Laboratory Chemical Fume Hood is a ventilated enclosure designed to protect laboratory personnel from inhaling hazardous chemical fumes, vapors, and dusts
  • Type
  • Other
  • Dimension (L*W*H)
  • 1200 Millimeter (mm)
  • Equipment Type
  • Blower Type- PP Centrifugal
  • Color
  • Multi Colour
  • Equipment Materials
  • Galvanized Iron
  • Material
  • GI Powder Coated
  • Application
  • Laboratory
  • Warranty
  • Lifetimee
 

Laboratory Fume Hood Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Delivery Time
  • 2 Week
 

Laboratory Fume Hood About

Laboratory Chemical Fume Hoodis a ventilated enclosure designed toprotect laboratory personnelfrom inhaling hazardous chemical fumes, vapors, and dusts by safely containing and exhausting them away from the breathing zone. It is one of the most essential safety devices in chemical laboratories.

Key Components
  1. Work Chamber:

    • The internal workspace where chemical operations are performed.

    • Often lined withchemical-resistant materialslike epoxy resin or stainless steel.

  2. Sash (Front Window):

    • A vertically or horizontally slidingtempered glass panel.

    • Protects the user while allowing controlled access to the workspace.

  3. Exhaust System:

    • Uses an electric blower or fan to draw air into the hood and out through a duct or filter system.

    • Ensures constant airflow to prevent fume escape.

  4. Airfoil and Baffles:

    • Optimize airflow across the work surface and direct contaminants toward the exhaust.

  5. Lighting:

    • Built-in, vapor-proof lighting provides clear visibility inside the hood.



Engineered for Laboratory Safety

Our Laboratory Fume Hood is thoughtfully designed to provide superior protection for laboratory personnel working with hazardous chemicals. The sturdy GI powder-coated structure offers durability and resistance to corrosion, while precise airflow management ensures effective containment of fumes and particles.


Advanced Control and Monitoring Features

Equipped with a digital display and intuitive keypad controls, this fume hood enables precise monitoring and adjustment of airflow. The rectangular design enhances workspace efficiency and supports a wide range of laboratory setups, making it ideal for various chemical handling applications.

FAQ's of Laboratory Fume Hood:


Q: How does the Laboratory Fume Hood protect users from hazardous chemicals?

A: The Laboratory Fume Hood works by creating a constant airflow that draws chemical fumes, vapors, and dusts away from the user, venting them through a PP centrifugal blower. This containment ensures laboratory operators remain protected from inhaling dangerous substances.

Q: What materials are used in the construction of this fume hood?

A: This fume hood is constructed from galvanized iron (GI) with a powder-coated finish, providing enhanced durability and resistance to corrosion. Its interior components are designed to withstand harsh chemical environments, ensuring longevity and safety.

Q: When should a laboratory fume hood be used?

A: A laboratory fume hood should be used whenever activities involve handling chemicals that produce toxic fumes, particulates, or vapors. It is essential during experiments, chemical reactions, or processes that could release harmful airborne substances.

Q: Where can this Laboratory Fume Hood be installed?

A: This fume hood is designed for laboratory environments in educational institutions, research centers, medical facilities, and industrial settings across India. Its rectangular, compact shape makes it suitable for standard laboratory benches.

Q: What is the process for operating the fume hood?

A: To operate the fume hood, power it on using the 220-240 V supply, set the required parameters on the digital display with the keypad, and ensure the blower is functioning. Always check that the airflow is properly directed before commencing any laboratory procedure.

Q: What are the key benefits of using this Laboratory Fume Hood?

A: The main benefits include enhanced user safety from hazardous fumes, ease of operation with digital controls, long-term durability from GI powder-coated construction, and assurance with a lifetime warranty. It promotes a safer, cleaner laboratory environment.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory Equipments Category

Benchtop Density Meter: DMA

Benchtop Density Meter: DMA

Price 65000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Type : Other

Voltage : 110240 V

Application : Laboratory

Equipment Materials : DD LAB

Water Bath Serological

Water Bath Serological

Price 35000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Type : Other

Voltage : 230 V Volt (v)

Equipment Materials : DD LAB

Laboratory Chemical Fume Hood, Outer material: GI powder coated, Hood width: 1200 mm

Laboratory Chemical Fume Hood, Outer material: GI powder coated, Hood width: 1200 mm

Price 182000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Type : Other

Application : Gas valve, Water tab, Vacuum valve, electrical sockets

Equipment Materials : GI powder coated

Round Oil Bath

Round Oil Bath

Price 34999.0 INR / Piece

Minimum Order Quantity : 1 Piece

Type : Other

Voltage : 230 VAC Volt (v)

Application : Laboratory

Equipment Materials : DDLAB