Back to top
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood
Laboratory Fume Hood

Laboratory Fume Hood

Price 182000.0 INR/ Piece

MOQ : 1 Unit

Laboratory Fume Hood Specification

  • Display Type
  • Digital
  • Shape
  • Rectangular
  • Control Type
  • Keypad
  • Temperature Resistance
  • Yes
  • Power Supply
  • 220-240 V
  • Usage
  • Laboratory Chemical Fume Hood is a ventilated enclosure designed to protect laboratory personnel from inhaling hazardous chemical fumes, vapors, and dusts
  • Type
  • Other
  • Dimension (L*W*H)
  • 1200 Millimeter (mm)
  • Equipment Type
  • Blower Type- PP Centrifugal
  • Equipment Materials
  • Galvanized Iron
  • Color
  • Multi Colour
  • Material
  • GI Powder Coated
  • Application
  • Laboratory
  • Warranty
  • Lifetimee
 

Laboratory Fume Hood Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Delivery Time
  • 2 Week
 

About Laboratory Fume Hood

Laboratory Chemical Fume Hoodis a ventilated enclosure designed toprotect laboratory personnelfrom inhaling hazardous chemical fumes, vapors, and dusts by safely containing and exhausting them away from the breathing zone. It is one of the most essential safety devices in chemical laboratories.

Key Components
  1. Work Chamber:

    • The internal workspace where chemical operations are performed.

    • Often lined withchemical-resistant materialslike epoxy resin or stainless steel.

  2. Sash (Front Window):

    • A vertically or horizontally slidingtempered glass panel.

    • Protects the user while allowing controlled access to the workspace.

  3. Exhaust System:

    • Uses an electric blower or fan to draw air into the hood and out through a duct or filter system.

    • Ensures constant airflow to prevent fume escape.

  4. Airfoil and Baffles:

    • Optimize airflow across the work surface and direct contaminants toward the exhaust.

  5. Lighting:

    • Built-in, vapor-proof lighting provides clear visibility inside the hood.



Engineered for Laboratory Safety

Our Laboratory Fume Hood is thoughtfully designed to provide superior protection for laboratory personnel working with hazardous chemicals. The sturdy GI powder-coated structure offers durability and resistance to corrosion, while precise airflow management ensures effective containment of fumes and particles.


Advanced Control and Monitoring Features

Equipped with a digital display and intuitive keypad controls, this fume hood enables precise monitoring and adjustment of airflow. The rectangular design enhances workspace efficiency and supports a wide range of laboratory setups, making it ideal for various chemical handling applications.

FAQ's of Laboratory Fume Hood:


Q: How does the Laboratory Fume Hood protect users from hazardous chemicals?

A: The Laboratory Fume Hood works by creating a constant airflow that draws chemical fumes, vapors, and dusts away from the user, venting them through a PP centrifugal blower. This containment ensures laboratory operators remain protected from inhaling dangerous substances.

Q: What materials are used in the construction of this fume hood?

A: This fume hood is constructed from galvanized iron (GI) with a powder-coated finish, providing enhanced durability and resistance to corrosion. Its interior components are designed to withstand harsh chemical environments, ensuring longevity and safety.

Q: When should a laboratory fume hood be used?

A: A laboratory fume hood should be used whenever activities involve handling chemicals that produce toxic fumes, particulates, or vapors. It is essential during experiments, chemical reactions, or processes that could release harmful airborne substances.

Q: Where can this Laboratory Fume Hood be installed?

A: This fume hood is designed for laboratory environments in educational institutions, research centers, medical facilities, and industrial settings across India. Its rectangular, compact shape makes it suitable for standard laboratory benches.

Q: What is the process for operating the fume hood?

A: To operate the fume hood, power it on using the 220-240 V supply, set the required parameters on the digital display with the keypad, and ensure the blower is functioning. Always check that the airflow is properly directed before commencing any laboratory procedure.

Q: What are the key benefits of using this Laboratory Fume Hood?

A: The main benefits include enhanced user safety from hazardous fumes, ease of operation with digital controls, long-term durability from GI powder-coated construction, and assurance with a lifetime warranty. It promotes a safer, cleaner laboratory environment.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory Equipments Category

Vertical Deep Freezer

Vertical Deep Freezer

Price 90000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Material : Stainless Steel

Application : Manual

Shape : Rectangular

Voltage : 220 Volt (v)

Ultrasonic Cleaning Machine

Ultrasonic Cleaning Machine

Price 56500.0 INR / Unit

Minimum Order Quantity : 1 Unit

Material : Stainless Steel 304

Application : Cleaning Jewellry, Lenses & Optical Parts, Watches, Dental & Surgical Instruments, Electronics, Automotive, Industrial Parts, Laboratory Glassware

Shape : Rectangular

Voltage : 220240 V, 50 Hz

Microprocessor Based Conductivity Tds Meter

Microprocessor Based Conductivity Tds Meter

Price 40000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Material : Plastic and Metal

Application : Water Quality Testing, Laboratory, Industrial Applications

Shape : Rectangular

Voltage : 230 V AC, 50 Hz

Anti Vibration Table

Anti Vibration Table

Price 30000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Material : Stainless Steel

Application : Laboratory

Shape : Square